How should an organization that installs a wireless network shielding device develop a system inspection and maintenance plan?

Dojammer 2023-11-14

After some large units install wireless network shielding devices, they often neglect the subsequent inspection and maintenance of the system. After a period of accumulation, several small problems may add up to a big problem, causing the entire system to be in poor operating status. Stable, then, how should these units that install wireless network shielding devices formulate system inspection and maintenance plans?

Here, based on many years of on-site experience, we put forward some common and relatively easy-to-implement suggestions:

1. Check and repair hardware faults in the wireless network shielding device to prevent network line outages and power supply line outages;

2. Carefully review whether each IP parameter in the software settings is unique, and whether the marked name and location match the actual installation location. The IP of each jammer terminal in the wireless network jammer is unique, and there should be no devices with overlapping IP addresses in the entire system;

3. Regarding the maintenance sequence of wireless network shielding devices: A: First check the IP setting errors and correct them; B: Use the software to first find out the jammer terminals that fail to communicate in the entire row, column or entire building. In most cases, For line problems, priority should be given to solving the network and power outage problems of the line; C: Scattered jammer terminals need to be checked one by one one by one.

3G 4G 5G Blocker

4. The fast and good operation of the entire wireless network shielding device is based on the premise that every device and every node in the system has normal power supply and normal network communication. When a single node or several branch lines are blocked in the system software, , the more accumulated the number is, the longer it will take to query the overall work status. Therefore, it is strongly recommended that after the complete overhaul of the system is completed again and returns to normal, assign a dedicated person to monitor and query each node on a regular basis. Once an individual node failure is discovered, it should be reported immediately and personnel should be arranged to repair and restore it. You can't just report it without repairing it, and you can't let it accumulate!

5. It is clearly stipulated that every node or equipment terminal in the entire set of wireless network shielding devices cannot cut off power or network without permission;

6. A designated person is responsible for establishing a ledger of daily inspection and maintenance records for this set of wireless network shielding devices.